As these models are discontinued, specifications provided are for information purposes only. |
| |
3 - 5 kW units |
 |
| Model |
RAP-3-24-1 |
RAP-3-48-1 |
RAP-5-48 |
RAP-5-110 |
RAP-5-120 |
Input voltages |
24 VDC |
48 VDC |
48 VDC |
110 VDC |
120 VDC |
Output voltage & frequency* |
240 Vac
50 or 60 Hz |
240 Vac
50 or 60 Hz |
240 Vac
50 or 60 Hz |
240 Vac
50 or 60 Hz |
240 Vac
50 or 60 Hz |
Continuous output @ 40°C |
2.7 kW |
3 kW |
5 kW |
5 kW |
5 kW |
1 hour rating @ 40°C |
3.2 kW |
3.6 kW |
6 kW |
6 kW |
6 kW |
½ hour rating @ 40°C |
3.5 kW |
3.9 kW |
6.5 kW |
6.5 kW |
6.5 kW |
Surge rating |
5.4 kW |
6 kW |
10 kW |
10 kW |
10 kW |
Maximum charge current |
90 A |
35 A |
83 A |
35 A |
35 A |
Peak efficiency |
> 90 % |
> 92 % |
> 92 % |
> 94 % |
> 94 % |
Power factor range |
0 - 1 |
0 - 1 |
0 - 1 |
0 - 1 |
0 - 1 |
Idle power |
35 W |
35 W |
50 W |
50 W |
50 W |
Standby power |
< 10 W |
< 10 W |
< 10 W |
< 10 W |
< 10 W |
Integrated isolation AC/DC |
cct breaker |
cct breaker |
cct breaker |
cct breaker |
cct breaker |
Indicators |
LED & LCD |
LED & LCD |
LED & LCD |
LED & LCD |
LED & LCD |
Inverter mass |
60 kg |
60 kg |
70 kg |
70 kg |
70 kg |
Data logging |
Yes |
Yes |
Yes |
Yes |
Yes |
Internal Gen contactor |
6 kVA |
6 kVA |
10 kVA |
10 kVA |
10 kVA |
External Gen contactor |
optional |
optional |
optional |
optional |
optional |
Remote access |
RS232 |
RS232 |
RS232 |
RS232 |
RS232 |
|
| |
10 - 15 kW units |
 |
| Model |
RAP-10-108
RAP-10-120
|
RAP-12-108
RAP-12-120 |
| Input voltages |
108 / 120 VDC |
108 / 120 VDC |
| Output voltage & frequency* |
240 Vac
50 or 60 Hz |
240 Vac
50 or 60 Hz |
| Continuous output @ 40°C |
10 kW |
12 kW |
| 1 hour rating @ 40°C |
12 kW |
14 kW |
| ½ hour rating @ 40°C |
13 kW |
15.6 kW |
| Surge rating |
22 kW |
22 kW |
| Maximum charge current |
70 A |
80 A |
| Peak efficiency |
> 94 % |
> 93 % |
| Power factor range |
0 - 1 |
0 - 1 |
| Idle power |
100 W |
120 W |
| Standby power |
30 W |
30 W |
| Autostart on demand |
Yes |
Yes |
| Mimimum start load |
12 - 15 W |
12 - 15 W |
| Integrated isolation AC/DC |
cct breaker |
cct breaker |
| Indicators |
LED & LCD |
LED & LCD |
| Inverter mass |
260 kg |
260 kg |
| Cooling system |
5 fans |
5 fans |
| Data logging |
Yes |
Yes |
| Internal DC cct breaker |
Yes |
Yes |
| Internal Gen contactor |
20 kVA |
20 kVA |
| Remote access |
RS232 |
RS232 |
|
| |
15 - 40 kW units |
 |
Model |
RAP-15-48
|
RAP-15-108
RAP-15-120
|
RAP-25-108
RAP-25-120 |
| Input voltages |
48 VDC |
108/120 VDC |
108/120 VDC |
| Operating DC voltage range |
42-62 V |
100-158 V |
100-158 V |
| Continuous output @ 40°C |
15 kW |
15 kW |
25 kW |
| 1 hour rating @ 40°C |
18 kW |
18 kW |
30 kW |
| ½ hour rating @ 40°C |
19.5 kW |
19.5 kW |
32.5 kW |
| Surge rating |
30 kW |
30 kW |
50 kW |
| Maximum charge current |
250 A |
120 A |
200 A |
| Peak efficiency |
> 91 % |
> 93 % |
> 93 % |
| Power factor range |
0 - 1 |
0 - 1 |
0 - 1 |
| Idle power |
< 150 W |
< 150 W |
< 250 W |
| Integrated isolation AC/DC |
cct breaker |
cct breaker |
cct breaker |
| Indicators |
LED & LCD |
LED & LCD |
LED & LCD |
| Inverter mass |
210 kg |
290 kg |
330 kg |
| Internal Gen contactor |
no |
< 30 kVA |
no |
| External Gen contactor |
required |
optional |
required |
|
| |
*AC output voltages of 110, 120, 220 and 230 are available on application.
* DC operating voltage range 92% to 130% of nominal. |
Common to all units:
- Automatic Bypass: Supply is maintained by the generator if the inverter is off line.
- Low distortion, high power load presented to generator during charging for best generator performance.
- All units available in 220 / 230 / 240 VAC 50 or 60 Hz output (240 / 415, 230 / 380V three phase plus neutral connection). 120 / 208 VAC on application.
- Data Logging Remote Access: RS232 port, standard data logging and remote access via modem, satellite, GSM and CDMA technology.
- Cooling: Convection and thermostatically controlled fans.
- Enclosures: Electronics IP50, transformer and heatsink IP23. Weatherproof enclosures or rack mounting are available on request.
- Protection: Over current trip, over voltage, over temperature, reverse polarity, fast electronic trip, transient over voltage protection.
Standards:
All inverters are designed to AS3100 / AS2604 / AS61000.3.5 and the draft AS/NZ standard for grid connect inverters.
Low distortion, high power presented to to generator during charging for best generator performance.
Refer to sales staff for details of applicable compliance testing.
Brochures
Brochures for all PSA inverters can be found here.
Remote Link Software
Remote link can be found here.
Application Notes
Application notes for Remote Area Power Systems inverters are available in
PDF format. To view these documents, you will need Adobe's
Acrobat Reader.
RAP Operation.pdf
This is a general description of RAPS inverter operation.
PSA Inverter
Programming Example.pdf
This is a worked example, showing how to set up the parameters of a RAPS
inverter for a solar-diesel remote power system. It was prepared by the Renewable
Energy Centre at the Brisbane North Institute of TAFE, as part of their Hybrid
Energy Systems course.
|