RAPS Inverter Specifications

Inverter
Model RAP-10-108
RAP-10-120
Discontinued
RAP-12-108
RAP-12-120
Discontinued
RAP-15-120
Input voltages 108 / 120 VDC 108 / 120 VDC 120 VDC
Output voltage & frequency* 240 Vac
50 or 60 Hz
240 Vac
50 or 60 Hz
240 Vac
50 or 60 Hz
Continuous output @ 40°C 10 kW 12 kW 15 kW
1 hour rating @ 40°C 12 kW 14 kW 18 kW
½ hour rating @ 40°C 13 kW 15.6 kW 19.5 kW
Surge rating 22 kW 22 kW 30 kW
Maximum charge current 70 A 80 A 100 A
Peak efficiency > 94 % > 93 % > 93 %
Power factor range 0 - 1 0 - 1 0 - 1
Idle power 100 W 120 W 150 W
Standby power 30 W 30 W 30 W
Autostart on demand Yes Yes Yes
Mimimum start load 12 - 15 W 12 - 15 W 12 - 15 W
Integrated isolation AC/DC cct breaker cct breaker cct breaker
Indicators LED & LCD LED & LCD LED & LCD
Inverter mass 260 kg 260 kg 280 kg
Cooling system 5 fans 5 fans 5 fans
Data logging Yes Yes Yes
Internal DC cct breaker Yes Yes Yes
Internal Gen contactor 20 kVA 20 kVA 20 kVA
Remote access RS232 RS232 RS232

 

Common to all units:

  • Automatic Bypass: Supply is maintained by the generator if the inverter is off line.
  • Low distortion, high power load presented to generator during charging for best generator performance.
  • All units available in 220 / 230 / 240 VAC 50 or 60 Hz output (240 / 415, 230 / 380V three phase plus neutral connection). 120 / 208 VAC on application.
  • Data Logging Remote Access: RS232 port, standard data logging and remote access via modem, satellite, GSM and CDMA technology.
  • Cooling: Convection and thermostatically controlled fans.
  • Enclosures: Electronics IP50, transformer and heatsink IP23. Weatherproof enclosures or rack mounting are available on request.
  • Protection: Over current trip, over voltage, over temperature, reverse polarity, fast electronic trip, transient over voltage protection.

Standards:

All inverters are designed to AS3100 / AS2604 / AS61000.3.5 and the draft AS/NZ standard for grid connect inverters.
Low distortion, high power presented to to generator during charging for best generator performance.
Refer to sales staff for details of applicable compliance testing.

Brochures

Brochures for all PSA inverters canbe found here.

Application Notes

Application notes for Remote Area Power Systems inverters are available in PDF format. To view these documents, you will need Adobe's Acrobat Reader.

RAP Operation.pdf

This is a general description of RAPS inverter operation.

PSA Inverter Programming Example.pdf

This is a worked example, showing how to set up the parameters of a RAPS inverter for a solar-diesel remote power system. It was prepared by the Renewable Energy Centre at the Brisbane North Institute of TAFE, as part of their Hybrid Energy Systems course.

 

*AC output voltages of 110, 120, 220 and 230 are available on application.
* DC operating voltage range 92% to 130% of nominal.