This software will enable you to connect to any capable inverter from your computer, via a direct serial cable connection or a dial-up modem, and operate the inverter with a virtual keypad.
SA series inverters
The layout is designed to match the physical keypad.
Remote Link also gives you the ability to download up to seven separate usage information files from a SA series inverter, to graph in Microsoft Excel or a similar package.
Shunt 1
Shunt 2
Shunt 3
Input 1
Input 2
Generator Run Time
Percentage Battery Charge
The files' output is regular .CSV format, ready for graphing in Microsoft Excel or your favorite viewer.
Selectronic PS1 and Power Solutions Australia inverters
For a PS1 or PSA inverter, Remote Link will download the data from either one selected day or the entire stored data contents.
Additionally, you can send Generator Start/Stop and Battery Equalise commands.
After downloading data, it is automatically converted for you according to the particular model detected, and graphs spreadsheets are created for viewing in Excel.
For Selectronic PS1 inverters only:
In the Selectronic PS1 models, a new LCD Mode even lets you remotely control the inverter using the same buttons available on the inverter's front panel.
New to Version 3.0, Remote Link 2008
Version 3.0 can now display and edit settings on a PS1, saving you from having to navigate the menu structure via the front panel. All settings are easily visible / adjustable at a glance.
The system is passcode protected against user editing, and installers' configuration sets can be loaded and saved to / from file by users.
Live readings can display a variety of settings simultaneously on one screen.
Licensing
Remote Link is available in varying levels of licensing, depending on the number of sites you need to connect. Please contact the sales department for more details.
*** NEW *** Starting from version 2.1, the program has no restriction on the number of inverter sites each licensed user may connect to.
Download
If you have a previous version of Remote Link 2006 or 2008, this latest release will automatically update over your previous installation; you will not need to re-enter any unlocking code or site information.
Without an unlocking code, the software will run for 14 days in evaluation mode.
In this mode, the software is fully functional except that you may only configure one inverter site.
To purchase an unlocking code, contact your local supplier. Your supplier will provide all support for the product.
RemoteLinkSetup.msi (1.2MB)
System Requirements
Functional Minimum
SA Series inverter (Or SE Series upgraded with Energy Management Mk II)
Any PS1 and most Power Solutions Australia inverters.
Note that not all PSA inverters are guaranteed to function with Remote Link.
Microsoft Windows 98 / 2000 / XP / Vista. Other operating systems not supported.
Internet Explorer 5.01 or higher.
12 MB hard disk space
If Microsoft .NET 2.0 Framework is not already installed then approx. 100 MB of additional disk space will be required.
500 MHz or faster processor.
64 MB RAM
Serial COM Port. Many USB-Serial adaptors work fine.
Either an external serial modem or a "null modem" (crossover) serial cable.
In addition to the above, the following is recommended for best performance:
Microsoft Windows 2000 / XP / Vista
Pentium 3, 1000 MHz or greater
800 x 600 or greater display area
256 MB RAM
We recommend and support only the NetComm Roadster (AM5698) modem,
and can supply one if required. However, most other modems will work just fine.